Solar Calculator Canada

Solar Power Calculator for Temiskaming Shores, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Temiskaming Shores
  • GPS Coordinates: 47.4936111, -79.7152778
  • Elevation: 246 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Temiskaming Shores: 39o
  • Average yearly irradiance: 1452.18 kWh/m2
  • Average yearly power output: 122818 kWh
Sun Path Temiskaming Shores

Average yearly irradiance delivered by the Sun in Temiskaming Shores is 1452.18/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 122818 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.21 68.39
February 3.16 88.58
March 4.39 136.03
April 4.95 148.44
May 5.57 172.68
June 5.53 166.04
July 5.63 174.65
August 5.2 161.06
September 4.34 130.26
October 3.05 94.65
November 2.08 62.29
December 1.58 49.1
Total yearly 1452.18

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 209.37 6490.54
February 296.86 8312
March 395.03 12246
April 424.08 12722.3
May 459.5 14244.7
June 444.52 13335.7
July 448 13887.9
August 416.29 12904.9
September 355.28 10658.5
October 259.59 8047.19
November 182.18 5465.3
December 145.25 4502.77
Total yearly 122818

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Temiskaming Shores solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 148.95 4617.46
February 233.56 6539.63
March 346.25 10733.9
April 412.87 12386.2
May 479.24 14856.6
June 478.8 14364.1
July 475.72 14747.2
August 417.67 12947.8
September 326.18 9785.34
October 217.05 6728.57
November 136.09 4082.85
December 101.37 3142.62
Total yearly 114932

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.48 5099.01
February 250.49 7013.6
March 360.9 11188
April 419.56 12586.8
May 479.5 14864.4
June 475.27 14258.1
July 473.7 14684.7
August 421.54 13067.7
September 336.1 10083
October 228.9 7095.88
November 148.03 4441.05
December 112.59 3490.24
Total yearly 117872

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.53 5534.55
February 265.53 7434.85
March 373.25 11570.6
April 423.98 12719.5
May 477.4 14799.5
June 469.9 14097
July 469.67 14559.6
August 423.29 13121.9
September 344.02 10320.6
October 239.23 7416.28
November 158.82 4764.55
December 122.77 3805.93
Total yearly 120145

Temiskaming Shores Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.08 5923.46
February 278.66 7802.58
March 383.26 11880.9
April 426.08 12782.5
May 472.8 14656.9
June 462.53 13875.9
July 463.88 14380.2
August 422.81 13107.1
September 349.91 10497.3
October 248.02 7688.72
November 168.41 5052.16
December 131.9 4089.02
Total yearly 121737

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -3.25% temperature and irradiance loss. This totals to about -15.43%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BoisbriandRosem�reSainte-Th�r�seSaint-AmableLorraineBois-des-FilionBrownsburg-ChathamCharlemagneSaint-ColombanMascoucheL'�piphanieBarkmereSaint-Joseph-de-SorelCap-Sant�NeuvilleSaint-Augustin-de-DesmauresSainte-Catherine-de-la-Jacques-CartierFossambault-sur-le-LacLac-SergentShannonLac-Saint-JosephLac-DelageSainte-Brigitte-de-LavalBeaupr�ColwoodMurdochville